Warning or Critical QoS alarms

Last Updated : Jan 25, 2022 |
Prolog information
Possible reasons for QoS alarms include:
  • The endpoint client may be having difficulties in generating a good packet stream.
  • The endpoint client NIC may be misconfigured or dropping packets
  • Missing or incorrect DSCP setting in Avaya Aura® MS configuration
  • Missing or incorrect DSCP settings or policies in network routers or switches
  • The network routers and switches between the client and the Avaya Aura® MS may be overloaded, dropping packets
  • The Codec selected by the client may not produce a quality audio experience at the network packet loss rate
  • Avaya Aura® MS may have been installed on a virtual machine (VM) that is improperly configured
  • Avaya Aura® MS NIC is dropping packets or incorrectly configured.

Proposed solutions

  • Examine endpoint client to ensure it is producing a quality packet stream.
  • Examine endpoint client NIC driver or configuration.
  • Examine Avaya Aura® MS DSCP setting to ensure they match the network policy
  • Examine client and network switch and routers settings to ensure they enforce the expected packet prioritization.
  • Examine network configuration to ensure network is not causing unexpected loss due to congestion or other factors
  • Choose higher quality Codecs compatible with network loss rate specification.
  • If Avaya Aura® MS is installed on a Virtual Machine, improper VM resource allocation/reservation can cause packets to be lost in the oncoming network drivers. Refer to “Deploying and Updating Avaya Aura® Media Server Appliance FP1” and follow all requirements and recommended best practices for VM configuration.
  • Examine Avaya Aura® MS server NIC configuration.
  • If the QoS alarms are determined to be due to Codec preference and network configuration decisions that cannot be changed, the options are:
    • Disable the QoS alarm, removing a useful warning of unexpected network problems.
    • Decrease thresholds for QoS warning or critical states such that normal observed levels of quality degradation do not trigger the alarms.
    • Increase numbers of sessions allowed in the warning or critical states before raising alarms.