Displaysexpansion module parameters. Expansion 1 is the EM200 connected to the CONNECTOR OUT 1 connector on the rear of the G430, and expansion 2 is the EM200 connected to the CONNECTOR OUT 2 connector on the rear of the G430.
Prolog information
Metadata
Keywords:
Syntax
show platform expansion [expansion-id]
Parameters
Parameter
Description
Possible Values
Default Value
expansion-id
The ID of the expansion module. If no ID is specified, parameters for both expansion modules are tested.
1,2
User level
read-only
Context
general
Example
To display the parameters of both expansion modules:
Gxxx-001(super)# show platform expansion Expansion Board #1 --------------------- Type : Expansion module Description : Expansion module for G430 Serial Number : 08IS30195733 HW Vintage : 0 HW Suffix : D Faults : No Fault Messages
MEDIA MODULE DESCRIPTION: v5 ------------------------------------------------- Not Installed
MEDIA MODULE DESCRIPTION: v6 ------------------------------------------------- Not Installed
Expansion module 1 MAIN POWER SUPPLY UNIT ------------------------------------------ Type : Expansion module PSU Description : Expansion module 1 Power Supply 175W Faults : No Fault Messages
Expansion module 1 POE POWER SUPPLY UNIT ----------------------------------------- Not Installed
FAN UNIT ------------------------- Type : Expansion Module fans Description : Expansion Module 1 fans Faults : Fail
Expansion Board #2 --------------------- Not Installed