test customer-alarm

Last Updated : Aug 14, 2023 |

Use test customer-alarm to test the customer provided alarm device by closing the alarm relay contact on the PN and EPN maintenance media module in a specified cabinet, including the TN2312BP, for 1 minute and then restoring the alarm relay contact to its current state. Verify the test by checking the customer alarm attached to the specified media module.

Syntax

test customer-alarm  UU C [ short | long  ][ repeat # | clear ][ schedule ]
location UU C

Extension of the data module or data channel to be tested, per dial-plan.

short

Execute a series of nondestructive diagnostic tests.

long

Execute a more comprehensive and longer version of the diagnostic tests. This may involve both destructive and nondestructive tests.

repeat #

Number of times to repeat the test.

clear

Repeat the test sequence until the alarm is cleared, or until a single test in the sequence fails.

schedule

Specify a start time for the command.

Example

test customer-alarm 
test customer-alarm  02  r  2
test customer-alarm  01b  r  25
test customer-alarm  2a 
test customer-alarm  2a  sh 
test customer-alarm  3  c