Use set options to administer the levels of alarm reporting.
Syntax
set options
set options field descriptions
Field
Description
Major
Set the alarm reporting type for the following major alarms:
On-board station alarms
Off-board station alarms
On-board trunk alarms (Alarm group 1)
Off-board trunk alarms (Alarm group 1)
On-board trunk alarms (Alarm group 2)
Off-board trunk alarms (Alarm group 2)
On-board trunk alarms (Alarm group 3)
Off-board trunk alarms (Alarm group 3)
On-board trunk alarms (Alarm group 4)
Off-board trunk alarms (Alarm group 4)
On-board adjunct link alarms
Off-board adjunct link alarms
Off-board DS1 alarms
Off-board TCP/IP link alarms
Off-board alarms (other)
Minor
Set the alarm reporting type for the following minor alarms:
On-board station alarms
Off-board station alarms
On-board trunk alarms (Alarm group 1)
Off-board trunk alarms (Alarm group 1)
On-board trunk alarms (Alarm group 2)
Off-board trunk alarms (Alarm group 2)
On-board trunk alarms (Alarm group 3)
Off-board trunk alarms (Alarm group 3)
On-board trunk alarms (Alarm group 4)
Off-board trunk alarms (Alarm group 4)
On-board adjunct link alarms
Off-board adjunct link alarms
Off-board MASI link alarms
Off-board DS1 alarms
Off-board TCP/IP link alarms
Off-board alarms (other)
Off-board ATM network alarms
Alarm reporting options
Option
Description
Minor
Alarms are raised as maintenance testing discovers them and the severity of the alarm is upgraded or downgraded to a minor. Alarmed resources that are normally taken out of service are still taken out of service. LEDs on the port board and maintenance board follow the normal minor alarm LED strategy and there is a call to the receiving OSS.
Warning
Alarms are raised as maintenance testing discovers them, and the severity of the alarm is downgraded to a warning. The advantage is that the Alarm Log can still be used to pinpoint trunk or station problems. Alarmed resources that are normally taken out-of-service are still taken out-of-service. Alarm LEDs light on the media module pack and Maintenance media module as before, but no attendant LEDs or stations reporting alarms are affected. There is no call to INADS.
Report
Downgrade the alarm to a warning and report the warning to INADS. This is not supported by Avaya.
Yes
Alarms are raised in the normal manner. There is no filtering of alarm data.
No
Alarms raised on a trunk, station, or adjunct in this category are dropped. Error information is provided, but there is no trace of an alarm. There is no LED activity and no call to INADS. Because resources are taken out-of-service without any record, you must use this option only when other options do not provide the desired result.