Use test data-module to perform hardware diagnostic tests on a data module or a data channel. Test results are determined by the interface to the digital switch-data line port, digital line port, or network control data channel.
Syntax
test data-module extension [ short | long ][ repeat # | clear ] [ schedule ]
extension
Extension of the data module to be tested (per dial-plan).
short
Execute a series of nondestructive diagnostic tests.
long
Execute a more comprehensive and longer version of the diagnostic tests. This may involve both destructive and nondestructive tests.
repeat #
Number of times to repeat the test.
clear
Repeat the test sequence until the alarm is cleared, or until a single test in the sequence fails.
schedule
Specify a start time for the command.
Example
test data-module 30000 ltest data-module 30000 test data-module 32000 sh r 2test data-module 33000 l r 25test data-module 30000 c