test ds1-facility

Last Updated : Aug 08, 2023 |

Use test ds1-facility to perform a series of tests on the specified facility. Each test runs diagnostics on the facility and returns results of the test along with any possible error codes. The long test is destructive and is not enabled unless the facility has been busied out.

Syntax

test ds1-facility location [ short  |  long  |  external loopback ][ repeat # ] [ schedule ]
location

Location of the DS1 Converter media module.

short

Run a series of nondestructive diagnostic tests.

long

Run a more comprehensive and longer version of the diagnostic tests. This may involve both destructive and nondestructive tests.

external loopback

This initiates a destructive test that sends a test pattern to an external device and returns it for comparison to the original. Configure the external device to loop back the signal. For more information, see Maintenance Alarms for Avaya Aura® Communication Manager, Branch Gateways Servers

repeat #

Number of times to repeat the test.

schedule

Specify a start time for the command.

Example

test ds1-facility 1v902