ADJ-IP error log entries

Last Updated : Jun 16, 2015 |
ADJ-IP Error Log Entries
Error Type
Aux Data
Associated Test
Alarm Level
On/Off Board
Command to resolve the error
0a
0
Any
Any
Any
test aesvcs link#
2b
Any
test aesvcs link#
18c
busyout port location
WRN
OFF
release aesvcs link#
257d
Any
ASAI Link Status Test (#1365)
MAJ MIN WRN1
OFF
test aesvcs link#
1025e
MAJ MIN WRN1
OFF
test aesvcs link#
3329f
ASAI Link Status Test (#1365)
MAJ MIN WRN1
OFF
test aesvcs link#
1 Alarms may be downgraded according to values set on the set options form.
a Error Type 0: Run the ASAI Link Status Test 1365 and follow its recommended procedures.
b Error Type 2: Too many Q931 protocol timeouts in a short time. No action to take.
c Error Type 18: The ASAI link has been busied out by command. To release the link, enter release aesvcs link#.
d Error Type 257: The ASAI TCP/IP link is not in an established state.
e Error Type 1025: TCP Tunnel Connection failure.
f Error Type 3329: ASAI TCP/IP link failure.