EMG-XFER error log entries and recommended actions

Last Updated : Sep 08, 2023 |
EMG-XFER error log entries
Error type
Aux data
Associated test
Alarm level
On or Off board
Command to resolve the error
0
0
Any
Any
Any
test environment UU
1
0
Emergency Transfer Query (#124)
MAJ
ON
test environment UU r 3
257
0
Emergency Transfer Query (#124)
WRN
ON
test environment UU r 3
Notes:
  1. Error type 0: Run the short test sequences first. If every tests passes, run the long test sequence. Refer to each appropriate test description and follow its recommended repair procedures.
  2. Error Type 1: the Emergency Transfer switch located on the Processor media module is set to the manual ON position up. When the Emergency Transfer switch is in this position, a Major alarm in generated.
  3. Error Type 257: the Emergency Transfer switch located on the Processor circuit pack is set to the manual OFF position down. When the Emergency Transfer switch is in this position, a Warning alarm is generated.