Dial plan manager denial events

Last Updated : Dec 08, 2021 |
Prolog information
Denial Events generated by the Dial Plan Manager denial events are listed in the following table.
Dial Plan Manager denial events (2400 - 2406)
EventType
Event Description, as it is displayed on the event log (keyword)
Explanation
Event Data 1
Event Data 2
2400
UDP: too many conversions
Digit conversion counter exceeded.
Partition number
Extension
2401
UDP: node-rte pat blank
Node number route pattern is blank.
Partition number
Node Number
2402
UDP: ENP code blank
ENP numbering prefix is blank.
Digit count
End point index
2403
Loc Digits Size incorrect
Location Prefix digits size is not n, where the UDP form’s matching row, Insert digits field is Ln.
Location
Number of digits to insert
2404
Var-in-Vec No adm for VAC
Variable Access Code (VAC) in Variables in Vector Table not administered.
Feature ID
Digit
2405
Var-in-Vec Invalid digit
Invalid digit entered, or Feature Access Code corrupted from call processing to dial plan manager.
Feature ID
Digit
2406
Unadministered annc ext
Unadministered announcement extension for a location.
Location
Internal return code
2408
Keypad dialing an enb-ext
Dialed an enb-ext using keypad
Location
Dialed digits
2409
Proxy RP no TG assigned
No trunk group assigned in route pattern for the proxy select route path field on the locations form.
Route pattern ID
Location
2410
DID AAR/ARS not Allowed
Allow AAR/ARS Access from DID/DIOD field set as number.
Feature ID
Port type
2411
extn valid but unassigned
Dialed number is valid according UDP form, but is unassigned. Dial Plan Parameter says to quit and not try other CTA route choices.
Location
Call type
2412
Off-PBX UID table full
Denial event for exceeding limit of XMUID table.
UID
Count of currently administered Xmuid_e entries
2413
Off-PBX Number table full
Denial event for exceeding limit of XMNUM table.
Xmobile UID
Count of currently administered Xmnum_e entries