ERR-LOG error log entries

Last Updated : Jul 08, 2015 |
Error type
Aux data
Associated test
Alarm level
On or Off Board
Command to resolve the error
510
See Note
none
none
none
Notes:
  1. Error type 510: An inconsistency was detected in either the Alarm Log, the Hardware Error Log, or the Software Error Log. The system attempts to recover the logs but, depending on the extent of the corruption, some or all entries in the logs may be lost. Any alarms that were active at the time of this error have been cleared. There is no associated test for this error.
    The Aux Data value indicates when the inconsistency was found:
    0
    During a periodic audit of the Error Log
    1
    After an extended reboot
    2
    After a reboot
    3
    After a Reset System 3 (Cold_1)
    4
    After a Level-3 System Reset (Cold_1)
    4
    After a Reset System 2 (Cold_2)
    8
    After a Level-2 System Reset (Cold_2)
    16
    After a Level-1 System Reset (Warm Start)
    100
    After an internal software audit
    2500
    After a single-process (MDM) restart