ASAI-BD (Multi-Application Platform Board)

Last Updated : Sep 29, 2023 |
Prolog information
MO Name in Log
Alarm Level
Initial Command to Run
Full Name of MO
ASAI-BD
MIN
WRN
test board location
ASAI-BD
See ASAI-PT (ASAI Port)and ASAI-EPT (ASAI Endpoint)for related line information. See the following exceptions listed below:
  • Hyperactivity: Currently, the common circuit pack is considered “hyperactive” if the circuit pack sends 200 uplink messages in a 10-second period. An alarm is issued when the limit reaches 400. When the limit reaches 500 uplink messages in 10 seconds, the board is taken out of service.
  • Port Administration: In Administration Without Hardware (AWOH), the switch allows administration of up to 8 ports in any of the first 12 ports. If the port type later reported by the board does not match the existing type, the switch assumes it to be a MAPD board with a different configuration and rejects the board.