Error Type
|
Aux Data
|
Associated Test
|
Alarm Level
|
On/Off Board
|
Command to resolve the error
|
|---|---|---|---|---|---|
|
513a
|
WRN
|
Off
|
none
|
||
|
769 b
|
AESVCS Link Heartbeat Test (#1624)
|
Log only
|
test aesvcs link link#
|
||
|
1537 c
|
Any
|
Log only
|
|||
|
2561 d
|
Log only
|
|
Aux Data
|
Description
|
|---|---|
|
1
|
The far end closed the socket connection. Check the error logs on the AEVCS Server for more information.
|
|
100
|
The reset aecvcs-link command was used to close the socket connection
|
|
101
|
The AESVCS Interface on the IP Services form was disabled.
|
|
102
|
The AESVCS Interface was removed from the IP Services form.
|
|
103
|
The AE Services Server was disabled on the AE Services Administration page of the IP Services form.
|
|
104
|
The AE Services Server was deleted on the AE Services Administration page of the IP Services form.
|
|
200
|
The socket connection closed due to an internal error. Escalate if the problem persists.
|
|
201
|
The socket connection was unexpectedly closed by Communication Manager. Escalate if the problem persists.
|
|
202
|
Communication Manager detected an error and closed the socket connection. Escalate if the problem persists.
|
|
203
|
Communication Manager detected an error reading from the socket and closed the connection. Escalate if the problem persists.
|
|
204
|
Communication Manager failed to write a complete message and closed the socket connection. Escalate if the problem persists.
|
|
205
|
AE Server established a new connection causing Communication Manager to close the existing one. Escalate if the problem persists.
|
|
206
|
Communication Manager failed to send a heartbeat request and closed the socket connection. Escalate if the problem persists.
|
|
207
|
Communication Manager detected a protocol violation and closed the socket connection. Escalate if the problem persists.
|
|
208
|
Communication Manager detected processing the data from the AESVCS Server and closed the socket connection. Escalate if the problem persists.
|
|
209
|
Communication Manager could not read data from the socket and closed the connection. Escalate if the problem persists.
|