AN-LN-PT (Analog Line Port)

Last Updated : Aug 29, 2023 |
Prolog information
MO Name in Log
Alarm Level
Initial Command to Run
Full Name of MO
AN-LN-PT
MIN
test port location l
Analog Line port
WRN
test port location
The MM711 Analog Trunk and Line Media Module provides 8 ports. The MM716 provides 24 ports. Each of the ports may be administered in any of several ways, as described in MG-ANA (Analog Media Module). Not all of the tests run on the media modules. These tests will abort with error code 1412. This error can be ignored.
Note:
Test #48 may cause some terminal equipment to ring briefly during daily maintenance. If this ringing disturbs the customer or the terminal equipment, disable it in the Tests field of the change station extension form. Be aware that this action also disables Tests #6, 7, 161, and 35 on some software releases.