RANL-STA (Remote Analog Line Station Port)

Last Updated : Jun 19, 2015 |
Prolog information
MO name in log
Alarm level
Initial command to run
Full name of MO
RANL-STA
MIN
test port location long
Remote Analog Line Port (RANL-STA)
WRN
test port location
The RANL-STA MO maintains the circuitry associated with a port which has been translated as analog station.
Failures of the neon message waiting lamp power and the common ringing application circuitry are reported as part of common port circuit pack errors. See errors 1281 and 1793 in XXX-BD (Common Port Circuit Pack/Media Module).
Note:
Test #48 may cause some terminal equipment to ring briefly during daily maintenance. If this ringing disturbs the customer or the terminal equipment, disable it in the Tests field of the change station extension screen. This also disables Test 35 on that station.