MG-DCP error log entries and recommended actions

Last Updated : Aug 25, 2020 |
MG-DCP Error Log Entries
Error type
Aux data
Associated test
Alarm level
On/Off board
Command to resolve the error
0 1
0
Any
Any
Any
test board location
1
0
Media Module removed or SAKI Sanity Failure (#53)
MIN
ON
18
0
busyout board location
WRN
OFF
release board location
23
0
None
WRN
OFF
125
None
MIN
ON
257
65535
Control Channel Looparound Test (#52)
MIN
ON
test board location r 20
513
Any
Angel Background Error
MIN
ON
test board location
769
4358
None
1025
4363
NPE Audit Test (#50)
1281
Ringing Application Test (#51)
MIN
ON
test board location r 2
1538
Any
None
WRN MIN
ON
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate test’s description, and follow its recommended procedures.
Notes:
  1. Error type 1: The media module stopped functioning or has been physically removed from the system. The alarm is logged approximately 11 minutes after removal of the media module or failure of the SAKI Sanity Test (#53).
    Check for the physical presence of the media module in the slot indicated by the alarm. If the media module is absent, insert one of the proper type. If the media module is present and its red LED is lit, see LED alarms without Alarm Log entry or with Error Type 1 in LED Descriptions for Avaya Aura® Communication Manager Hardware Components.
  2. Error type 18: The media module has been busied out. Release the media module using release board location.
  3. Error type 23: The media module has been logically administered but not physically installed. The alarm should clear when the media module is installed.
    If the media module is already installed:
    1. Run test board location long and look at any test failures or Error Codes generated.
    2. If the test does not clear error 23, then execute reset board location and run the long test again.
    3. If the reset/test does not clear error 23, replace the media module.
  4. Error type 125: The media module physically installed in the slot does not match the type that is administered for that slot. Do one of the following:
    • Remove the incorrect media module and replace it with one of the type that is administered for that slot.
    • Use change circuit-pack or change media-gateway n to re-administer the slot so that it matches the board that is installed, and follow with reset board location.
  5. Error type 257: Transient communication problems between the switch and this circuit pack or media module. Execute test board location and refer to the repair procedures for the Control Channel Looparound Test 52.
  6. Error type 513: An on-board hardware failure was detected. The system will continuously test the media module and report the results approximately every 10 minutes. If the hardware problem is resolved, the alarm should clear in approximately 30 minutes. If the alarm does NOT clear in 30 minutes, then the media module should be replaced.
  7. Error type 769: This error can be ignored, but look for other errors on this media module.
  8. Error type 1025: This error is not service-affecting and no action is required.
  9. Error type 1281: This error is not service-affecting and no action is required.
  10. Error type 1538: The hyperactive media module is out-of-service and may exhibit one or more of the following symptoms:
    1. The media module level tests such as Test #51 and/or Test #220 are aborting with Error Code 2000.
    2. The tests run on the ports of this media module are returning with a NO-BOARD.
    3. A busyout/release of the media module has no effect on test results.
    4. A list configuration command shows that the media module and ports are properly installed.
    Check the alarm level. If the alarm level is a WARNING, users are probably causing the hyperactivity by adjusting or changing their digital stations. If the media module is very hyperactive, this alarm will be upgraded to a MINOR alarm within 1 hour. If the alarm level is a MINOR alarm, then replace the media module.