Find answers to your technical questions and learn how to use our products
Search suggestions:
Find answers to your technical questions and learn how to use our products
Search suggestions:
|
Error type
|
Aux data
|
Associated test
|
Alarm level
|
On/Off board
|
Command to resolve the error
|
|---|---|---|---|---|---|
|
0
|
0
|
Any
|
Any
|
Any
|
test pms-link
|
|
18
|
0
|
busyout pms-link
|
WRN
|
OFF
|
release pms-link
|
|
257
|
Any
|
Link Retry test (#215)
|
MIN WRN1
|
OFF
|
test pms-link l
|
|
513
|
Any
|
test pms-link
|
|||
|
769
|
Any
|
||||
|
1025
|
40–49
|
||||
|
1281
|
10–19
|
||||
|
1537
|
N0–N9
|
||||
|
1793
|
Any
|
test pms-link
|
|||
|
2049
|
Any
|
||||
|
2305
|
50–59
|
release pms-link, or
test pms-link
|
|||
|
2561
|
Any
|
test pms-link
|
|||
|
2817
|
100–109 200–209 300–309
|
||||
|
3073
|
70–79
|
||||
|
3841
|
20–29
|
|
10x
|
The PMS violated the application protocol. The first message after a request to initiate a database exchange was not the start of a database exchange. The message is processed. If this Error Type with this aux data value occurs frequently (more than once a month), advise the customer to call the vendor of the PMS to check out the PMS device. Once the PMS Link is successfully established, this error disappears from the Error Log.
|
|
20x
|
The PMS violated the application protocol. The start of a database exchange was received in a state in which it was not expected. The message is ignored. If this Error Type with this Aux data value occurs frequently (more than once a month), advise the customer to call the vendor of the PMS to check out the PMS device. Once the PMS Link is successfully established, this error disappears from the Error Log.
|
|
30x
|
The PMS violated the application protocol. The end of a database exchange was received when no exchange was in progress. The message is ignored. If this Error Type with this Aux Data value occurs frequently (more than once a month), advise the customer to call the vendor of the PMS to check out the PMS device. Once the PMS Link is successfully established, this error disappears from the Error Log. No alarm is raised against this error.
|