SP-REG-M (Survivable Processor-Main)

Last Updated : Jul 06, 2015 |
Prolog information
MO name in log
Alarm level
Initial command to run
Full name of MO
SP-REG-M
MAJ
MIN
None
Survivable Processor-Main
The Survivable Processor object monitors keep-alive message between the main server and the survivable processor, which can be either:
  • Survivable Remote Server
  • Survivable Core Server
The server exchanges keep-alive messages with each of the survivable processors. If the server does not receive a predetermined number of those messages, both the server and the survivable processor alarm. If a Survivable Remote Server does not register with a Survivable Core Server, it registers with either the main server or another Survivable Core Server and alarms are not raised.
Possible causes for SP-REG-M alarms include:
  • The network is down.
  • The server or survivable processor administration is incorrect.