Find answers to your technical questions and learn how to use our products
Search suggestions:
Specifies how the contact closure relay is controlled.
The set contact-closure pulse-duration command does not affect the set contact-closure admin manual command.
set contact-closure admin module/port:relay {mgc | manual-trigger | manual-off}
Parameter
Description
Possible Values
Default Value
module
Module number of the contact closure port
10
port
Port number of the contact closure port
2
relay
Contact closure relay
1 , 2
mgc
Contact closure is controlled by the call controller
manual-trigger
Contact closure relay is triggered
manual-off
Contact closure relay is not triggered
read-write
general
To specify that contact closure for relay 2 of port 1 on module 10 is controlled by the call controller:
Gxxx-001(super)# set contact-closure admin 10/1:2 mgc
Previous Topic