set slot-config

Last Updated : Aug 16, 2023 |

Defines the slot and the board type in the Branch Gateway for SLS.

Syntax

set slot-config slot-number board-type

Parameters

Parameter

Description

Possible Values

Default Value

slot-number

Identifies the slot number

See the following table.

board-type

Defines the allowable board type

Table 1: Slot and board matrix for SLS

Media Module

Description

Permitted slots

SLS configured?

MM710

One T1/E1 trunk port

v1, v2, v3, v5, v6, v7, v8

Yes

MM711

Eight universal analog ports

v1, v2, v3, v5, v6, v7, v8

Yes

MM712

Eight DCP telephone ports

v1, v2, v3, v5, v6, v7, v8

Yes

MM714

Four analog trunk ports and four analog station ports

v1, v2, v3, v5, v6, v7, v8

Yes

MM714B

Four analog trunk ports, four analog station ports, and an emergency transfer relay

v1, v2, v3, v5, v6, v7, v8

Yes

MM716

Twenty-four analog telephone ports. May alternatively be used as DID trunk ports.

v1, v2, v3, v5, v6, v7, v8

Yes

MM717

Twenty-four high density DCP telephone ports

v1, v2, v3, v5, v6, v7, v8

Yes

MM720

Eight BRI trunk ports

v1, v2, v3, v5, v6, v7, v8

Yes

MM721

Eight BRI trunk ports

v1, v2, v3, v5, v6, v7, v8

Yes

MM722

Two BRI trunk ports

v1, v2, v3, v5, v6, v7, v8

Yes

S8300

Processor/LSP (display only)

v1, v5

No

User level

read-write

Context

sls

Example

To define the slot type as v1 and the board type as MM720 in the Branch Gateway:

Gxxx-001 (super-sls)# set slot-config v1 MM720