Updating the governing rule for Historical Reporting

Last Updated : Apr 08, 2021 |
Prolog information
You can update the default governing rule to change the view of a historical report.
Note:
Ensure that you apply the appropriate filters at the input prompts so that you get optimum results.
  1. Log in to the Cluster Control Manager (CCM) console as the customer user.
  2. Switch to being the root user by entering the command su.
  3. To run the Analytics Administration script, use the following command:
    ADDITIONAL INFORMATION:
    ccm release orca analytics
  4. Select Historical Reporting by pressing the corresponding number.
  5. Select Historical Reporting Configuration by pressing the corresponding number.
  6. To update the default governing rule for returning the number of records for a report, select the Governing Rule option.
    ADDITIONAL INFORMATION:
    At the prompt to enter the Administrator password, enter your administrator password.
  7. In the Proceed with setting governing rules? option, type y.
    ADDITIONAL INFORMATION:
    Typing n cancels the operation.
  8. In the Maximum number of rows field, enter the maximum number of rows that you can view in a historical report.
    ADDITIONAL INFORMATION:
    The default value is 32,000 rows.
  9. In the Maximum number of elements field, enter the maximum number of elements returned in prompt values.
  10. In the Maximum number of intermediate rows field, enter the maximum number of intermediate result rows to view in a report.
    STEP RESULT:
    The CCM console displays that the updates are complete.
  11. Return to the main menu by entering m.
  12. Quit the current page by entering q.