IP Office Configuration for Switch Resilience

Last Updated : May 16, 2018 |
For DECT switch resilience, the IP Office is configured as shown below. Only the primary IP Office needs this configuration. However, for provisioned systems, the security service user on the fallback IP Office must be enabled and configured to match the settings entered for the redundant provisioning connection.
Prolog information
  1. Receive the IP Office configuration.
  2. Click on Line. The list of existing lines is displayed.
  3. Select the IP DECT Line.
  4. Select the Gateway tab.
  5. In the Enable Resiliency section, select Enable Resiliency.
  6. Only change the other values if necessary:
    • Status Enquiry Period: This field set how frequently (in seconds) the master base station should check the status of the primary IP Office. For a non-provisioned installation, this value should match the Status Inquiry Period set in the master base station.
    • Prioritize Primary: If selected, when during fallback the primary IP Office returns to normal operation, DECT control is automatically returned to it. If not selected, the fallback IP Office retains control until it is manually returned using the System Status application.
    • Supervision Timeout: This field sets how long after contact is lost (in seconds) before the master base station should fallback to the fallback IP Office system. This option is only accessible here for a provisioned installation. For a non-provisioned installation the value is set through the master base station.
  7. Click OK.
  8. Save the settings back to the system.