Maintenance features for G450 Branch Gateway and G430 Branch Gateway

Last Updated : Jan 08, 2024 |
Table 1: Maintenance features for G450 Branch Gateway and G430 Branch Gateway

Supported feature

Controller Duplicated Servers

Notes

Attendant Console alarm LED and alarm report acknowledgement LED

Yes

Status of G450 Branch Gateway and G430 Branch Gateway alarms is not available on the Attendant Console with a legacy controller.

Automatic Trunk Measurement System (ATMS)

No

Not available for analog trunks terminating on a Media Module.

This test aborts when attempting a test call on these trunk groups:
  • ISDN-PRI

  • SIP

  • DID

  • Any incoming trunk group (transmission tests can only be run on outgoing trunks)

DS0 Looparound connection

No

DS1 CPE Loopback

Yes

Test is controlled by the DS1 Media Module.

DS1 Synchronization

Yes

Synchronization can be controlled by the Communication Manager server or locally on the G430 Branch Gateway and G450 Branch Gateway.

Enable/Disable Media Module tests

Yes

Enable/Suspend alarm origination

No

Not supported by Duplicated Server platform.

ISDN loop around connection

Yes

ISDN test call

No

Not available for ISDN trunks terminating on a DS1 Media Module.

LED tests

Partial

Works with Media Module LEDs but not with G430 Branch Gateway and G450 Branch Gateway alarm LED.

System Configuration Maintenance Object

No

Not needed for Media Module board insertion. Indicates that a board is present but that the board does not respond to a query for board type.

System Link test for PRI control link for ISDN DS1 Media Module

No

Layer 2 of a PRI link is terminated in G430 Branch Gateway and G450 Branch Gateway. A new MO is added for the status and alarming of H.248 links.

System tone test call for G430 Branch Gateway and G450 Branch Gateway

No

Requires changes to the call processing software in the G450 Branch Gateway and G430 Branch Gateway.

TDM Time Slot test call

No

Terminating Trunk Transmission test

No

Test MO command

Yes

Support syntax of Media Module location

Test of G450 Branch Gateway and G430 Branch Gateway resources:

Archangel

Network Control Element

Packet Interface

TDM clock

Tone generator

Tone detectors

No

Provided by G450 Branch Gateway and G430 Branch Gateway. G450 Branch Gateway and G430 Branch Gateway architecture specifies these resources as G450 Branch Gateway and G430 Branch Gateway resources.

Tests of Media Modules

Partial

Touch Tone Receiver facility test call

No

TTRs in G450 Branch Gateway and G430 Branch Gateway are not available outside the gateway.

Touch Tone Receiver level

No

TTRs in G450 Branch Gateway and G430 Branch Gateway are not available outside the gateway.

Trunk facility test call

Yes

Write Physical Angel command

No

System synchronization

Yes