Attendant Console alarm LED and alarm report acknowledgement LED |
Yes |
Status of G450 Branch Gateway and G430 Branch Gateway alarms is not available on the Attendant Console with a legacy controller. |
Automatic Trunk Measurement System (ATMS) |
No |
Not available for analog trunks terminating on a Media Module.
This test aborts when attempting a test call on these trunk groups:
|
DS0 Looparound connection |
No |
|
DS1 CPE Loopback |
Yes |
Test is controlled by the DS1 Media Module. |
DS1 Synchronization |
Yes |
Synchronization can be controlled by the Communication Manager server or locally on the G430 Branch Gateway and G450 Branch Gateway. |
Enable/Disable Media Module tests |
Yes |
|
Enable/Suspend alarm origination |
No |
Not supported by Duplicated Server platform. |
ISDN loop around connection |
Yes |
|
ISDN test call |
No |
Not available for ISDN trunks terminating on a DS1 Media Module. |
LED tests |
Partial |
Works with Media Module LEDs but not with G430 Branch Gateway and G450 Branch Gateway alarm LED. |
System Configuration Maintenance Object |
No |
Not needed for Media Module board insertion. Indicates that a board is present but that the board does not respond to a query for board type. |
System Link test for PRI control link for ISDN DS1 Media Module |
No |
Layer 2 of a PRI link is terminated in G430 Branch Gateway and G450 Branch Gateway. A new MO is added for the status and alarming of H.248 links. |
System tone test call for G430 Branch Gateway and G450 Branch Gateway |
No |
Requires changes to the call processing software in the G450 Branch Gateway and G430 Branch Gateway. |
TDM Time Slot test call |
No |
|
Terminating Trunk Transmission test |
No |
|
Test MO command |
Yes |
Support syntax of Media Module location |
Test of G450 Branch Gateway and G430 Branch Gateway resources: Archangel Network Control Element Packet Interface TDM clock Tone generator Tone detectors |
No |
Provided by G450 Branch Gateway and G430 Branch Gateway. G450 Branch Gateway and G430 Branch Gateway architecture specifies these resources as G450 Branch Gateway and G430 Branch Gateway resources. |
Tests of Media Modules |
Partial |
|
Touch Tone Receiver facility test call |
No |
TTRs in G450 Branch Gateway and G430 Branch Gateway are not available outside the gateway. |
Touch Tone Receiver level |
No |
TTRs in G450 Branch Gateway and G430 Branch Gateway are not available outside the gateway. |
Trunk facility test call |
Yes |
|
Write Physical Angel command |
No |
|
System synchronization |
Yes |
|