Last Updated : Nov 06, 2012 |

Enters RTR configuration mode and specify an identification number for an RTR operation. Use no rtr to delete the RTR.

You cannot enter configuration mode for a specific RTR if this RTR is currently probing an object. First deactivate the RTR using the no rtr-schedule command.

You cannot delete an RTR being monitored by an object tracker. First remove the link between them, using the no track track-id command.

Syntax

rtr rtr-id

Parameters

Parameter

Description

Possible Values

Default Value

rtr-id

The RTR ID

1-30

User level

read-write

Context

general

Example

To enter RTR configuration mode for RTR operation 1:

Gxxx-001(config)# rtr 1