Identifies a list of DS1 modules that are controlled by the primary D-channel in SLS.
This command applies only to ISDN-PRI trunks in a NFAS-managed group.
This command is not valid unless the slot configuration has already been administered (see set slot-config).
Note:
The North American Public Network Service Providers do not allow any part of a T1 to be shared outside of this NFAS-trunk group. You must adhere to the following rules:
All members of an NFAS DS1 that are administered must belong to the same trunk-group.
All members of this trunk-group must belong to a single signaling group.
Syntax
add nfas-interface {gateway module [interface-id>
Parameters
Parameter
Description
Possible Values
Default Value
gateway
Three-digit gateway number. For example, 005.
module
Two-character slot number. For example, v3. This number identifies a port on an already-provisioned DS1 board module.
interface-id
The DS1 circuit number that is associated with the NFAS group. This number must be coordinated with the public network service provider so that the signaling protocol operates correctly.
0-31
User level
read-write
Context
sls > sig-group
Example
To identify a list of DS1 modules that are controlled by the primary D-channel for gateway 005, module v5, and DS1 circuit number 0: