Example
To show information for all existing RMON alarms:
Gxxx-001(super)# show rmon alarm
alarm 1 is active, owned by billp
Monitors ifEntry.1.218106371 every 20 seconds
Taking delta samples, last value was 0
Rising threshold is 500, assigned to event # 1
Falling threshold is 100, assigned to event # 2
On startup enable rising or_falling alarms