The Signaling Group screen

Last Updated : Nov 01, 2016 |

Procedure

  1. Enter the display signaling-group xx command to view the Signaling Group screen. Where xx is the signaling group number.
  2. Specify the TSC related fields in the upper-right corner of the field.

    The following are relevant fields:

    • Max number of NCA TSC

    • Trunk group for NCA TSC

  3. Set the Supplementary Services Protocol field to b.

Result

A sample of the Signaling Group screen configured for BSR polling over IP without the B-channel is as follows.

display signaling-group 32 
                                SIGNALING GROUP 
 Group Number: 32             Group Type: h.323   
                           Remote Office? n          
Max number of NCA TSC: 10
                                                      Max number of CA TSC: 10
                                                   Trunk Group for NCA TSC: 32
       Trunk Group for Channel Selection: 32 
        Supplementary Service Protocol: b
        Network Call Transfer? n
        Near-end Node Name: clan-01D12       Far-end Node Name: cland12-loop 
      Near-end Listen Port: 1720             Far-end Listen Port: 1720 
                                             Far-end Network Region: 
              LRQ Required? n                Calls Share IP Signaling Connection?y
              RRQ Required? n
                                             Bypass If IP Threshold Exceeded?n
                                              Direct IP-IP Audio Connections?y
                                                        IP Audio Hairpinning?y
                                              Interworking Message: PROGress