These features relate to applications that access the system configuration settings using older security methods.
Field
Description
System Password
Range = 0 to 31 characters.
The system password is for the following:
  • IP Office Manager access to upgrade IP Office IP500 V2 systems.
  • UDP/TCP access by SysMonitor if the Monitor Password password is blank.
Voicemail Password
Default = Blank. Range = exactly 31 characters.
For IP Office 11.1 FP1 and higher versions, the password for voicemail connection is enforced to 31 characters.
  • This password is also set through the Voicemail Pro client and Web Manager application.
  • When no password is set, an auto generated password is automatically set on both Voicemail Pro client and Web Manager systems.
Monitor Password
Default = Blank. Range = 0 to 31 characters.
This password is used by SysMonitor for UDP and TCP access. If blank, then SysMonitor uses the System Password.
If changing this password with no previous password set, enter the system password as the old password.
Use Service User Credentials
Default = Off.
If enabled, SysMonitor access using UDP or TCP, uses service user names and passwords rather than the Monitor Password. The service user must also be a member of a rights group with System StatusSystem Monitor - Access enabled.
Application Controls
These check boxes control which actions the system will support for legacy applications. Different combinations are used by the different applications. A summary of the applications affected by changes is listed in the Application Support list.
  • For Linux-based IP Office servers, some ports, such as port 69 and 80, are also controlled by the SolutionPlatform ViewSettingsSystemFirewall Settings.
Field
Description
TFTP Server
Default = On.
TFTP Directory Read
Default = Off.
Used by Avaya Wireless DECT for IP Office contacts if using an AIWS.
TFTP Voicemail
Default = Off.
Program Code
Default = On.
Controls use of the upgrade wizard from within IP Office Manager.
DevLink
Default = On.
Control for DevLink applications, including UDP, TCP and HTTP access by SysMonitor.
TAPI/DevLink3
Default = Off.
Controls support for connections from TAPI and DevLink3 applications.
HTTP Directory Read
Default = On.
Allows system directory accessed using HTTP rather than HTTPS.
HTTP Directory Write
Default = On.
Allow HTTP rather than HTTPS to import temporary directory records into the system directory.