Last Updated : Aug 30, 2026 |
Navigation: ApplicationsVoicemail Pro - System PreferencesAlarms
Prolog information
Resource Id: appsVMPro107
The Voicemail Pro client can display the alarm calls that have been configured for the Voicemail Pro to perform.
The Voicemail Pro is limited to 2 outgoing alarm calls at the same time (subject to voicemail port availability). Any additional alarm calls are delayed until the existing alarm calls have been completed.
Field
Description
Add Alarm
Click to configure the following alarm settings.
Target
Time
Default = 00:00.
Set the alarm time in 24-hour format (hh:mm or hhmm). A time value can be entered or a call variable can be used. If left blank or if the call variable used is not a valid time value, the call flow user will be asked to enter a time the same as if Ask Caller was selected.
Frequency
Default = Single.
Sets how often the alarm should occur. The options are:
  • Single
  • Daily
  • Weekly
Day
Default = Today.
Set the day for the alarm. You can select a specific day or Today.
File
Default = Blank.
Optional. If a file is specified here it is used for the alarm call. If no file is specified the default alarm message "This is an alarm call, please hang up” is used.
Display Text
Default = Blank.
By default the alarm will display "Alarm" on the target if it is an Avaya display telephone. This field can be used to customize the text used.
Ring Time
Default = 60 seconds. Range = 5 to 120 seconds.
Set the length of ring time used for the alarm call if not answered.
Retries
Retries: Default = 0 (Off). Range = 0 to 10.
Used to specify how many times the alarm should be repeated if it is not answered and cleared. When a value other than 0 is selected, the Interval option becomes available to specify the interval between repeats.
Interval
Default = Blank (Off).
If a number of retires is specified, this option can be used to select the number of minutes between repeated alarm attempts until the alarm is cleared.
Enable Cancel Code
Default = No.
When off, the alarm is cleared if the alarm call is answered. When on, a dialing code can be specified. If the correct code is not dialed in response to an alarm, the alarm is not cleared and will repeat if retries have been specified.
Cancel Code
Default = * , Range = Up to 4 digits.
used to enter the dialing required to clear the alarm call. The value * will match any dialing. To cancel the alarm, the cancel code must be entered followed by the hash key (#). The file used to play the alarm message must mention the cancel code and the fact that cancel code must be followed by the hash key (#).
Alarms
The following additional fields are displayed in the Alarms table.
Created
Time on phone when the alarm was created
Next Activation
When the next alarm is going to get triggered
Type
When
Number