Performing optional FAC administration for value variables

Last Updated : Sep 08, 2012 |

About this task

This section describes the administration steps to use value variables in vectors and to use an FAC to change the variable assignments.

Use the following screen to administer an FAC.

change feature-access-codes                              Page x of x

                      FEATURE ACCESS CODE (FAC)

                    Call Vectoring/Call Prompting Features

   Converse Data Return Code: ____

Vector Variable 1 (VV1) Code: ____
Vector Variable 2 (VV2) Code: ____
Vector Variable 3 (VV3) Code: ____
Vector Variable 4 (VV4) Code: ____
Vector Variable 5 (VV5) Code: ____
Vector Variable 6 (VV6) Code: ____
Vector Variable 7 (VV7) Code: ____
Vector Variable 8 (VV8) Code: ____
Vector Variable 9 (VV9) Code: ____

To administer an FAC, perform the following steps:

Procedure

  1. On the Call Vector/Call Prompting Features page of the Feature Access Code screen, enter an FAC code in the field next to one of the Vector Access Code (VAC) entries.

    The FAC code must be a 1 to 4 digit string, but either a pound (#) or an asterisk (*) can be substituted for a numeral at the first digit position.

  2. Note the VVX value associated with the new FAC code.

    Possible VAC entries range from VV1 to VV9. You must enter this value in the VAC field on the Variables for Vectors screen when you administer the value variable to be associated with the FAC.