Dial plan manager denial events

Last Updated : Dec 08, 2021 |

Denial Events generated by the Dial Plan Manager denial events are listed in the following table.

Table 1: Dial Plan Manager denial events (2400 - 2406)

EventType

Event Description, as it is displayed on the event log (keyword)

Explanation

Event Data 1

Event Data 2

2400

UDP: too many conversions

Digit conversion counter exceeded.

Partition number

Extension

2401

UDP: node-rte pat blank

Node number route pattern is blank.

Partition number

Node Number

2402

UDP: ENP code blank

ENP numbering prefix is blank.

Digit count

End point index

2403

Loc Digits Size incorrect

Location Prefix digits size is not n, where the UDP form’s matching row, Insert digits field is Ln.

Location

Number of digits to insert

2404

Var-in-Vec No adm for VAC

Variable Access Code (VAC) in Variables in Vector Table not administered.

Feature ID

Digit

2405

Var-in-Vec Invalid digit

Invalid digit entered, or Feature Access Code corrupted from call processing to dial plan manager.

Feature ID

Digit

2406

Unadministered annc ext

Unadministered announcement extension for a location.

Location

Internal return code

2408

Keypad dialing an enb-ext

Dialed an enb-ext using keypad

Location

Dialed digits

2409

Proxy RP no TG assigned

No trunk group assigned in route pattern for the proxy select route path field on the locations form.

Route pattern ID

Location

2410

DID AAR/ARS not Allowed

Allow AAR/ARS Access from DID/DIOD field set as number.

Feature ID

Port type

2411

extn valid but unassigned

Dialed number is valid according UDP form, but is unassigned. Dial Plan Parameter says to quit and not try other CTA route choices.

Location

Call type

2412

Off-PBX UID table full

Denial event for exceeding limit of XMUID table.

UID

Count of currently administered Xmuid_e entries

2413

Off-PBX Number table full

Denial event for exceeding limit of XMNUM table.

Xmobile UID

Count of currently administered Xmnum_e entries