Restoring the CDR Link

Last Updated : Sep 18, 2023 |

About this task

Procedure

Procedure

  1. Determine the status of CDR links.

    Enter status cdr-link, and ensure that the CDR links are not busied out for maintenance. If the link is down, continue to the next step.

  2. Where does the CDR link connect to?

    Enter display system-parameters features , and find out the destinations of CDR links. Continue to the next step.

  3. Enter status data extension, and verify whether the data extension is in the in-service or idle state. If the data extension is not available, look for the extension number in the Alt Name field of the error log and see XXX-BD (Common Port Circuit Pack/Media Module) for resolutions.
  4. Is the external CDR output device available?

    Ensure that the CDR output device is on-line and ready for service. Check the physical connectivity between data module and the CDR output device.

  5. If the problem is not found in the above steps, check the PROCR for any problems.

Result

When restoring the CDR link, it is necessary to execute maintenance test on different objects that comprise the CDR link. It is recommended that you busyout the CDR link before trying to restore the link. When the CDR Link is busied out, then every CDR Link maintenance action is deactivated, and interference to tests of other MOs is prevented.