AN-LN-PT (Analog Line Port)

Last Updated : Aug 29, 2023 |

MO Name in Log

Alarm Level

Initial Command to Run

Full Name of MO

AN-LN-PT

MIN

test port location l

Analog Line port

WRN

test port location

The MM711 Analog Trunk and Line Media Module provides 8 ports. The MM716 provides 24 ports. Each of the ports may be administered in any of several ways, as described in MG-ANA (Analog Media Module). Not all of the tests run on the media modules. These tests will abort with error code 1412. This error can be ignored.

Note:

Test #48 may cause some terminal equipment to ring briefly during daily maintenance. If this ringing disturbs the customer or the terminal equipment, disable it in the Tests field of the change station extension form. Be aware that this action also disables Tests #6, 7, 161, and 35 on some software releases.