Firmware download problems

Last Updated : Dec 04, 2014 |

You cannot start a station download while there are active FW-STDL alarms. To clear all active FW-STDL alarms, use test firmware station-download. In the event of an FW-STDL alarm, you can find more details by using the status firmware station-download command.


status firmware station-download                          Page   1 of   1
                       STATUS FIRMWARE STATION DOWNLOAD
Image File: 2420v01.bin
Schedule Download? y                    Continue daily until completed?: y
Start Date/Time: 10/15/2006  20:00      Stop Date/Time: 10/15/2006  23:00
                                        Status for this download: Active
Terminal type for download: 2420
Extension Range: 85001   to: 86000      Number of stations in range: 35
Stations completed: 0                   Stations unsuccessful: 1
Extension Status Error   Extension Status Error   Extension Status Error
85001     ABRT  513
85002     ACTV
85017     ACTV
85034     ACTV

This command displays the Extension of the terminal, the Status, and a Error code if applicable. All aborted (ABRT), failed (FAIL), and actively downloading (ACTV) terminals are listed on this screen; pending or completed downloads are not listed. See the table for a list of these errors and their descriptions.