Line-side terminating device procedures

Last Updated : Sep 22, 2023 |

About this task

If the DS1 Media Module connects to a line-side terminating device such as a PRI terminal adapter, complete the following steps.

Procedure

  1. Verify that the switch DS1 and the line-side terminating device are administered using the same signaling mode, framing mode, and line coding.
  2. Investigate the maintenance status of the line-side terminating device.

    Refer to the Line-Side Terminating Device Operating Manual for information.

  3. Contact the vendor of the line-side terminating device to diagnose the equipment.
  4. Check the physical connection of the DS1 board to the terminating device, and check the premise distribution system or the intra-premise wiring for physical connection failures.
  5. Replace the local DS1 Media Module and repeat the test.