_PE 2 Minor alarm: PE on the other server is not responding

Last Updated : Nov 06, 2014 |
MO name in log

_PE 2

Alarm level

MIN

Alarm text

Can't ping the other server over the network used by the PE Interface.

Cause

Processor Ethernet (PE) on the other server is not responding. Cannot ping the other server over the network used by the Processor Ethernet interface.

Proposed Solution

Procedure

  1. Log on to Communication Manager SMI.
  2. Click the Administration tab and select Server (Maintenance).
  3. On the left navigation menu, click Status Summary. The system displays Status Summary screen.
  4. Verify that the other server in the duplicated server pair is running and that the Processor Ethernet status is not Down.
    1. If the other server in the duplicated server pair is not running, the status of Mode is Not Ready and the display of items such as Alarms are blank.
    2. If he Processor Ethernet status is not Down, run the troubleshooting procedures for the alarms on the other server.

    Execute the Ping diagnostic test to verify that the other server responds to a ping test. If it does not, execute the Ping diagnostics test from the other server to verify that it is connected to the corporate LAN.