Cause
The standby server could not process the interchange request of the active server. The interchange does not occur, and the active side remains active.
Proposed Solution 1
Procedure
- From the Server section of the web interface, select Status Summary to see if the standby side is Reset.
- To manually clear the alarm, select Current Alarms and the appropriate alarm, and click Clear.
- If the problem persists, troubleshoot the standby server:
- Check if the standby side is Reset. From the Server section of the web interface, select Status Summary.
- Check for application problems by selecting View Process Status and restore any applications with problems.
- Check for problems with an Ethernet interface by selecting the Execute Ping diagnostic. Check both sides of each failed link, and make necessary repairs.
- If the applications and interfaces are okay but the problem persists, go to the Avaya Support website at http://support.avaya.com to open a service request.