PRI endpoint service state OOS/NE

Last Updated : Nov 20, 2014 |

Alarm

WRN

Cause

Port has been busied out by command.

Proposed Solution 1

Procedure

Enter release pri-endpoint extension.

Alarm

MIN

Cause

NPE Crosstalk test (#6) failed.

Proposed Solution 2

Procedure

Replace UDS1 circuit pack.

Alarm

None

Cause

UDS1 circuit pack lost its signal.

Proposed Solution 3

Procedure

Check if the UDS1 circuit pack is removed. Check if the UDS1 cable disconnected. Check if the far-end terminal is restarting or experiencing problems. Check circuit pack using UDS1-BD procedure.