Table 1: PRI-CDR error log entries
Error type |
AUX data |
Associated test |
Alarm level |
On/off board |
Command to resolve the error |
0 |
0 |
Any |
Any |
Any |
test cdr-link primary | secondary |
18 |
0 |
busyout cdr-link primary|secondary |
WRN |
Off |
release cd-link primary | secondary |
257 |
Any |
Link Retry test (#215) |
MIN1 WRN |
Off |
test cd-link primary | secondary l |
513 |
|
|
|
|
test cdr-link primary | secondary |
1025 |
|
|
|
|
|
1281 |
Any |
|
|
|
|
1 Minor alarms may be downgraded to Warning alarms based on the value used in set options.
Notes:
Error type 0: Run the short test sequence first. If every test passes, run the long test sequence. Refer to each test’s description, and follow its procedures.
Error type 18: The CDR link is busied out and the CDR link is torn down.
Error type 257: Link Retry test (#215) failed. An error was detected when setting up the link. See the preceding section Procedures for Restoring the CDR Link resolution.
Error type 513: The CDR physical link is down for one of the following reasons:
Cable to the CDR output device is disconnected.
CDR output device is powered off.
The data extension where the CDR output device connects to has been busied out or there is a scheduled daily interchange.
Check the connectivity of wire and cable among wall jacket, data module, and the CDR output device.
Enter status data extension and verify that the data extension of the CDR output device is in the in-service/idle state. If the data extension is not available, see Procedures for Restoring the CDR Link for resolution.
Use display system-parameters maintenance to see the start time of daily maintenance.
If the error occurs and is resolved during of daily maintenance, it can be ignored.
Error type 1025: The CDR output device is in an off-line state, for example, due to paper jam or paper out for a printer device. The CDR link is torn down.
Check the CDR output device and act promptly to put it back to online state.
Enter test cdr-link primary | secondary command to set up the CDR link.
Error type 1281: Overflow of CDR records generated in the switch due to the heavy trunk traffic and low speed CDR output device. If both primary and secondary links are ON, the secondary link is torn down temporarily for two minutes to speed up the output process to the primary link. No action is necessary for this Error type.