Table 1: ADJ-IP Error Log Entries
Error Type |
Aux Data |
Associated Test |
Alarm Level |
On/Off Board |
Command to resolve the error |
0a |
0 |
Any |
Any |
Any |
test aesvcs link# |
2b |
Any |
|
|
|
test aesvcs link# |
18c |
|
busyout port location |
WRN |
OFF |
release aesvcs link# |
257d |
Any |
ASAI Link Status Test (#1365) |
MAJ MIN WRN1 |
OFF |
test aesvcs link# |
1025e |
|
|
MAJ MIN WRN1 |
OFF |
test aesvcs link# |
3329f |
|
ASAI Link Status Test (#1365) |
MAJ MIN WRN1 |
OFF |
test aesvcs link# |
1 Alarms may be downgraded according to values set on the set options form.
a Error Type 0: Run the ASAI Link Status Test 1365 and follow its recommended procedures.
b Error Type 2: Too many Q931 protocol timeouts in a short time. No action to take.
c Error Type 18: The ASAI link has been busied out by command. To release the link, enter release aesvcs link#.
d Error Type 257: The ASAI TCP/IP link is not in an established state.
e Error Type 1025: TCP Tunnel Connection failure.
f Error Type 3329: ASAI TCP/IP link failure.