Table 1: EMG-XFER error log entries

Error type

Aux data

Associated test

Alarm level

On or Off board

Command to resolve the error

0

0

Any

Any

Any

test environment UU

1

0

Emergency Transfer Query (#124)

MAJ

ON

test environment UU r 3

257

0

Emergency Transfer Query (#124)

WRN

ON

test environment UU r 3

Notes:

  1. Error type 0: Run the short test sequences first. If every tests passes, run the long test sequence. Refer to each appropriate test description and follow its recommended repair procedures.

  2. Error Type 1: the Emergency Transfer switch located on the Processor media module is set to the manual ON position up. When the Emergency Transfer switch is in this position, a Major alarm in generated.

  3. Error Type 257: the Emergency Transfer switch located on the Processor circuit pack is set to the manual OFF position down. When the Emergency Transfer switch is in this position, a Warning alarm is generated.