P_POMAGT18

Last Updated : Jun 03, 2026 |
Alarm code
Q_POMAGT18
Event code
P_POMAGT18
Alarm level
Major
Event level
Information
Event text
Failed to connect to CMS.
Throttle interval
3600
Trigger component
POM Agent Manager.

Problem description

POM generates this event when the RT socket connection to POM with CMS breaks.

Proposed solution

Procedure

  1. Ensure Call Management System (CMS) details, that is the IP address and port number, are configured on POM in Avaya Experience Platform™ On-Prem configuration.
  2. Ensure that the POM IP address and port number are configured on CMS.
  3. The CMS details configured on POM in Avaya Experience Platform™ On-Prem configuration should match the port number configured on CMS.
  4. If configuration is error free, then verify that the CMS session is running.