Type change system-parameters features. Press Enter.
STEP RESULT:
The system displays the Feature-Related System Parameters screen.
In the Authorization Code Enabled field, type y to enable the Authorization Codes feature on a system-wide basis.
In the Authorization Code Length field, type the number of digits that you want for the authorization code.
ADDITIONAL INFORMATION:
This field defines the length of the Authorization Codes your users need to enter. To maximize the security of your system, Avaya recommends that authorization codes must have at least 4 digits, but no more than 13 digits.
In the Authorization Code Cancellation Symbol field, leave the default of the pound sign (#).
ADDITIONAL INFORMATION:
Users must dial this symbol to cancel the 10-second wait period during which your user can enter an authorization code.
In the Attendant Time Out Flag field, leave the default of n.
ADDITIONAL INFORMATION:
When you set this field to
In the Display Authorization Code field, type n.
ADDITIONAL INFORMATION:
When you set this field to set to
Press Enter to save your changes.
Type change authorization-code n, where n is the authorization code. Press Enter.
STEP RESULT:
The system displays the Authorization Code - COR Mapping screen.
In the AC field, type the authorization code that your users must dial.
ADDITIONAL INFORMATION:
The number of digits in the code that you type must be the same as the number you assigned in the Feature-Related System Parameters screen.
In the COR field, type a COR number from 0 through 95.