Administering the Out of Band Management of management data

Last Updated : May 02, 2016 |
Prolog information
  1. Log in to Communication Manager SMI.
  2. Click AdministrationServer (Maintenance).
  3. In the navigation pane, click Server ConfigurationNetwork Configuration.
  4. Configure the following eth1 fields:
    ADDITIONAL INFORMATION:
    • IPv4 Address: The IP address of the Ethernet connection
    • Mask: The subnetwork mask of the IP address
    • Functional Assignment: Out-of-Band Management
    If the Communication Manager instance is a duplex configuration, configure the eth2 fields.
  5. Verify that you can gain access to Communication Manager using the Out-of-Band Ethernet interface.
    ADDITIONAL INFORMATION:
    Important:
    You must be able to gain access to Communication Manager using the Out of Band Management Ethernet interface before you perform the next step.
  6. Add a static route between the Out of Band Management interface and the enterprise network.
    ADDITIONAL INFORMATION:
    You must ensure that you add a static route between the Out of Band Management interface and the enterprise network to restrict access. For more information, see Add a static route between the Out of Band Management interface and the enterprise network.
  7. From the Restrict Management traffic to Out-of-Band interface is currently drop-down list, select enabled.
    ADDITIONAL INFORMATION:
    Note:
    Restrict Management traffic to Out-of-Band interface is set to enabled. Restrict Management traffic to Out-of-Band will restrict traffic on ports 80, 443, 22, 2222, 5022, 23, 5023, 161, and 162 to the management interface only.