Setting up Voice Paging over loudspeakers

Last Updated : Oct 02, 2023 |
Prolog information
  1. Enter change paging loudspeaker.
  2. In the Voice Paging Timeout field, type the maximum number of seconds that a page can last.
  3. In the Port field for Zone 1, type the port number that is assigned to the auxiliary media module to this zone.
  4. In the Voice Paging - TAC field, type the value for Trunk Access Code (TAC) that users dial to page this zone.
  5. In the Voice Paging - COR field, type the class of restriction (COR) for this zone.
    ADDITIONAL INFORMATION:
    You can assign different CORs to different zones.
  6. In the Location field on the Zone 1 row, type a descriptive name for the zone.
    ADDITIONAL INFORMATION:
    Use this name to help you remember the corresponding physical location.
  7. Repeat steps 4 through 6 for each zone.
  8. In the ALL row of the Voice Paging- TAC field, type the value for Trunk Access Code (TAC) that users dial to page all zones.
  9. In the All row of the Voice Paging - COR field, type the class of restriction (COR) for all zones.
    ADDITIONAL INFORMATION:
    When you complete this row, you allow users to page all zones at once. You do not have to assign a port to this row.
  10. Press Enter to save your changes.
    ADDITIONAL INFORMATION:
    You can integrate loudspeaker voice paging and call parking. This is called deluxe paging. You enable deluxe paging by entering
    Note:
    To set up paging on an H.248 gateway, connect the paging system to a port on an MM711 and administer the port as an analog station on the Station screen. No entries on the Loudspeaker Paging screen are required.