Activating Off-Premises Station for a user

Last Updated : Jul 30, 2021 |
Prolog information
  1. Enter change station n, where n is the extension of the user for whom you want to activate an off-premises station.
  2. In the Off-Premises Station field, perform the following actions:
    • If the telephone associated with this Station screen is not located in the same building as the server, type y.
      If you type y, you must administer the R Balance Network field on the Station screen.
    • If the telephone associated with this Station screen is located in the same building as the server, type n.
  3. In the R Balance Network field, perform one of the following actions.
    • Type y to select the R Balance Capacitor network. Type y in all other cases, except for the following cases:
    • Type n:
      • To select the standard resistor capacitor network
      • When the station port circuit is connected to the terminal equipment. Terminal equipment includes, for example, SLC carriers or impedance compensators. These are optioned for 600-ohm input impedance and the distance between the server and the equipment is less than 3,000 feet (914.4 meters).
      You must complete the R Balance Network field if the Off-Premises Station field on the Station screen is set to