E1-R2 Advanced

Last Updated : Apr 21, 2016 |

Navigation: System Settings > Line > E1–R2 Advanced

These settings must be edited offline. To enter offline editing, select Menu Bar Current User Icon > Offline Mode.

Field

Description

Zero Suppression

Default = HDB3

Selects the method of zero suppression used (HDB3 or AMI).

Clock Quality

Default = Network

Refer to the IP Office Installation Manual for full details. This option sets whether the system should try to take its clock source for call synchronization and signalling from this line. Preference should always be given to using the clock source from a central office exchange if available by setting at least one exchange line to Network.

  • If multiple lines are set as Network, the order in which those lines are used is described in the IP Office Installation Manual. If additional lines are available, Fallback can be used to specify a clock source to use should the Network source not be available.

  • Lines from which the clock source should not be taken should be set as Unsuitable.

  • If no clock source is available, the system uses its own internal 8KHz clock source.

  • In scenarios where several systems are network via digital trunk lines, care must be taken to ensure that all the systems use the same clock source. The current source being used by a system is reported within the System Status Application.

Line Signaling

Default = CPE

The options are:

  • CPE

  • CO

  • CO

The feature is intended to be used primarily as a testing aid. It allows T1 and E1 lines to be tested in a back-to-back configuration, using crossover (QSIG) cables.

The CO feature operates by modifying the way in which incoming calls are disconnected for system configuration in Brazil and Argentina. In these locales, the CO setting uses Forced-Release instead of Clear-Back to disconnect incoming calls. The Brazilian Double-Seizure mechanism used to police Collect calls, is also disabled in CO mode.

Incoming Routing Digits

Default = 4

Sets the number of incoming digits used for incoming call routing.

CRC Checking

Default = On

Switches CRC on or off.

Default All Group Settings

Default the MFC Group tab settings.

Line Signaling Timers

To edit one of these timers, either double-click on the timer or right-click on a timer and select the action required.