SIP DECT Base

Last Updated : Mar 14, 2024 |

Navigation: System Settings > Line > Add/Edit Trunk Line > Legacy SIP DECT Line > SIP DECT Base

The IP Office can support up to four D100 Base Stations. Each connects to the IP Office using a Legacy SIP DECT Line.

These settings are not mergeable. Changes to these settings requires a reboot of the system.

Field

Description

Line Number

Default = Blank. A unique line number associated with the SIP DECT Base Station.

Associated Extensions

Lists the SIP DECT extensions associated with the line through the extension's SIP DECT Line setting.

Base Name

Default = Blank. Maximum 16 characters.

A name assigned to the base station. Each base station provisioned on the IP Office must have a unique name. The field cannot be blank. The format is an alphanumeric string with no special characters.

Base MAC Address

Default = Blank.

The MAC Address of the base station. If only one base station is provisioned, the field can remain at the default value. If multiple base stations are provisioned, the MAC address for each base station must be entered.

Configure Base IP

Configure Base IP

Default = Off.

Set to On to configure IP address attributes for the base station. When enabled, the Configure Base IP settings are displayed.

DHCP Client

Default = On.

When enabled, specifies that the base station operates as a DHCP client. When enabled, not other IP address attributes can be configured.

IP Address

Default = Blank.

The IP address of the base station. The IP address must be on the same subnet as one of the LAN interfaces.

IP Mask

Default = Blank.

IP address mask.

IP Gateway

Default = Blank.

The default gateway address

Provisioning Server

Default = IP Office interface address.

The server address from where the Base Station configuration files can be retrieved.

Description

Default = Blank. Maximum 31 characters.

You can use this field to enter a description for the configuration entry. The description is not used elsewhere.