Administering Administered Connections

Last Updated : Dec 08, 2021 |

Procedure

  1. Choose one of the following data modules and administer all fields:
    • Data Line Data Module (use with Data Line circuit pack)

    • Processor/Trunk Data Module (use with one of the following:)

      • MPDMs, 700D, 7400B, 7400D, or 8400B

      • MTDMs, 700B, 700C, 700E, or 7400A

    • Processor Interface Data Module (for more information, see Administering Network Connectivity on Avaya Aura® Communication Manager.)

    • 25 Data Module (for more information, see Administering Network Connectivity on Avaya Aura® Communication Manager.)

    • 7500 Data Module (use with ISDN Line 12-BRI-S-NT or ISDN Line 12-BRI-U-NT circuit pack)

    • World Class Core BRI Data Module (use with wcbri)

  2. On the DS1 Circuit Pack screen, administer all fields.

    Use with switch node carriers.

  3. On the Access Endpoint screen, administer all fields.
  4. On the Trunk Group screen, choose one of the following trunk groups and administer all fields.
    • ISDN-BRI

    • ISDN-PRI

    • Tie

  5. On the Class of Restriction screen, administer all fields.
  6. On the Class of Service screen, administer all fields.
  7. On the Dial Plan Parameters screen, administer the Local Node Number field with a number from 1-63 that matches the DCS switch node number and the CDR node number.
  8. On the Administered Connection screen, administer all fields.
  9. On the Station screen, assign one button as ac-alarm.
  10. On the Attendant Console screen, assign one button as ac-alarm.