Setting up a signaling group

Last Updated : Aug 24, 2023 |

About this task

Each Remote Office has its own listen port and signaling group. Set up a new trunk group, or use an existing trunk group administered for H.323 signaling. To set up the signaling group for remote office:

Procedure

  1. Type add signaling-group and the number of the group you want to add.

    The system displays the Signaling Group screen.

  2. In the Group Type field, type H.323
  3. In the Remote Office field, type y.
  4. In the Trunk Group for Channel Selection field, type the number of the trunk you set up for the remote office.
  5. In the Near-end Node Name field, identify the node name assigned to the PROCR that supports the R300.
  6. In the Far-end Node Name field, identify the node name assigned to the PROCR that supports the R300.
  7. In the Near-end Listen Port field, type a port number in the 5000-9999 range.
  8. In the Far-end Listen Port field, type 1720.
  9. In the RRQ field, type y.
  10. Tab to the Direct IP-IP Audio Connection field on another page of this screen, and type y.
  11. Press Enter to save your changes.