Registering the endpoint

Last Updated : Jun 08, 2021 |
Prolog information
The Device Adapter follows the CS 1000 registration process. The user may be required to configure the IP connectivity, Node ID, and TN of the endpoint during registration, or may choose to change the values already on the endpoint. This information is protected by the Node password if the password is enabled.
The UNIStim station typically is not a new install. It will have already been set up to run within the CS 1000 IP Line service. Therefore, the “change a node ID and TN” procedure is shown here. None the less, the same general procedure applies for a newly installed UNIStim endpoint.
A 2050 soft client is used for the illustrations; an endpoint with a smaller display may require switching across pages to carry out the same operations.
  1. Bring up the connection service data entry screen. Use one of the following:
    1. The station reboot password.
    2. Power cycling the endpoint. (For a 2050 soft client, close the application and re-open.)
    3. Disconnecting the endpoint from the LAN long enough to reboot.
    ADDITIONAL INFORMATION:
    If the password is not required, the Connect Svc screen appears for 5 seconds.
    Otherwise, the password is displayed instead of the TN.
  2. Use the left or right arrow to access the correct field to edit. For example, pressing the right arrow puts the cursor at the right side of the first field (Node). Pressing the left arrow puts the cursor at the end of the “unit” of the TN.
  3. Add the node ID if it is not available or edit the node ID if it is incorrect. BKSpace clears the last character, Clear clears all characters, and OK accepts whatever is currently in the fields.
  4. If required, enter the password and press OK.
  5. If the password is not required, or the password is accepted, edit the TN. The field is formatted with the sub-fields aaa.bb.cc.dd. When the sub-field needs less than the full number of characters (for example, the “loop” 32 in the three-character loop field), enter the data as mentioned earlier.
  6. Press OK to log in. Several screens slashes in the display area as the different UNIStim and SIP messages are passed, but finally, registration completes.
    ADDITIONAL INFORMATION:
    The user’s UNIStim endpoint is registered.